{"product_id":"sellstrom-sentrywash®-90455-series-pedestal-mounted-eye-wash-station","title":"Sellstrom SentryWash® 90455 Series Pedestal Mounted Eye Wash Station","description":"\u003cp data-start=\"96\" data-end=\"575\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"100\" data-end=\"172\"\u003eSellstrom SentryWash® 90455 Series Pedestal Mounted Eye Wash Station\u003c\/strong\u003e is a heavy-duty, plumbed emergency eyewash system designed to provide immediate eye and face flushing in industrial workplaces where exposure to chemicals, dust, or hazardous substances may occur. Featuring a freestanding pedestal-mounted design, dual spray heads, and hands-free activation, the unit delivers a controlled flow of clean water to help minimize eye injuries during workplace emergencies.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"577\" data-end=\"869\"\u003eAvailable with either an \u003cstrong data-start=\"602\" data-end=\"639\"\u003eimpact-resistant ABS plastic bowl\u003c\/strong\u003e or a \u003cstrong data-start=\"645\" data-end=\"669\"\u003estainless steel bowl\u003c\/strong\u003e, the SentryWash 90455 Series is suitable for manufacturing plants, laboratories, chemical processing facilities, workshops, and industrial environments requiring permanent emergency eyewash stations.\u003c\/p\u003e\n\u003chr data-start=\"871\" data-end=\"874\"\u003e\n\u003ch5 data-start=\"876\" data-end=\"905\"\u003eKey Features \u0026amp; Benefits\u003c\/h5\u003e\n\u003cul data-start=\"907\" data-end=\"1516\"\u003e\n\u003cli data-section-id=\"1nk02e3\" data-start=\"907\" data-end=\"932\"\u003eModel Series: \u003cstrong data-start=\"923\" data-end=\"932\"\u003e90455\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"198cv93\" data-start=\"933\" data-end=\"986\"\u003ePedestal-Mounted Plumbed Emergency Eye Wash Station\u003c\/li\u003e\n\u003cli data-section-id=\"1a4drs\" data-start=\"987\" data-end=\"1015\"\u003eANSI\/ISEA Z358.1 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"2dd9b2\" data-start=\"1016\" data-end=\"1051\"\u003eOSHA 29 CFR 1910.151(c) Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1cmgfpe\" data-start=\"1052\" data-end=\"1087\"\u003eEN 15154-1 \u0026amp; EN 15154-2 Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"n90ayi\" data-start=\"1088\" data-end=\"1137\"\u003eHands-Free Activation with Stay-Open Ball Valve\u003c\/li\u003e\n\u003cli data-section-id=\"nxouet\" data-start=\"1138\" data-end=\"1179\"\u003eHighly Visible Epoxy-Coated Flag Handle\u003c\/li\u003e\n\u003cli data-section-id=\"1hwb6wf\" data-start=\"1180\" data-end=\"1214\"\u003eOptional Foot Treadle Activation\u003c\/li\u003e\n\u003cli data-section-id=\"iyp7ak\" data-start=\"1215\" data-end=\"1265\"\u003eDual Flood Spray Heads for Balanced Eye Flushing\u003c\/li\u003e\n\u003cli data-section-id=\"152q9c\" data-start=\"1266\" data-end=\"1296\"\u003eSelf-Regulating Flow Control\u003c\/li\u003e\n\u003cli data-section-id=\"wvvakr\" data-start=\"1297\" data-end=\"1340\"\u003eFloat-Off Dust Covers Protect Spray Heads\u003c\/li\u003e\n\u003cli data-section-id=\"18dhgop\" data-start=\"1341\" data-end=\"1367\"\u003eIntegrated Water Filters\u003c\/li\u003e\n\u003cli data-section-id=\"1e7lphi\" data-start=\"1368\" data-end=\"1415\"\u003eHeavy-Duty Chrome-Plated Brass Valve Assembly\u003c\/li\u003e\n\u003cli data-section-id=\"dfhycn\" data-start=\"1416\" data-end=\"1463\"\u003eRugged Galvanized Steel Pedestal Construction\u003c\/li\u003e\n\u003cli data-section-id=\"f8pvdn\" data-start=\"1464\" data-end=\"1516\"\u003eAvailable with ABS Plastic or Stainless Steel Bowl\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1518\" data-end=\"1521\"\u003e\n\u003ch5 data-start=\"1523\" data-end=\"1541\"\u003eApplications\u003c\/h5\u003e\n\u003cul data-start=\"1543\" data-end=\"1775\"\u003e\n\u003cli data-section-id=\"54d3n7\" data-start=\"1543\" data-end=\"1571\"\u003eChemical Processing Plants\u003c\/li\u003e\n\u003cli data-section-id=\"11nl0i3\" data-start=\"1572\" data-end=\"1598\"\u003eManufacturing Facilities\u003c\/li\u003e\n\u003cli data-section-id=\"19g68yh\" data-start=\"1599\" data-end=\"1621\"\u003eIndustrial Workshops\u003c\/li\u003e\n\u003cli data-section-id=\"ku3rl9\" data-start=\"1622\" data-end=\"1636\"\u003eLaboratories\u003c\/li\u003e\n\u003cli data-section-id=\"t5wk36\" data-start=\"1637\" data-end=\"1659\"\u003eOil \u0026amp; Gas Facilities\u003c\/li\u003e\n\u003cli data-section-id=\"ja4efv\" data-start=\"1660\" data-end=\"1683\"\u003ePharmaceutical Plants\u003c\/li\u003e\n\u003cli data-section-id=\"1ci7zj8\" data-start=\"1684\" data-end=\"1703\"\u003eMining Operations\u003c\/li\u003e\n\u003cli data-section-id=\"qsx0ct\" data-start=\"1704\" data-end=\"1728\"\u003eWater Treatment Plants\u003c\/li\u003e\n\u003cli data-section-id=\"1kn4xd\" data-start=\"1729\" data-end=\"1748\"\u003eMaintenance Areas\u003c\/li\u003e\n\u003cli data-section-id=\"wdjnd6\" data-start=\"1749\" data-end=\"1775\"\u003eEducational Laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1777\" data-end=\"1780\"\u003e\n\u003ch5 data-start=\"1782\" data-end=\"1812\"\u003eTechnical Specifications\u003c\/h5\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1814\" data-end=\"2742\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1814\" data-end=\"1841\"\u003e\n\u003ctr data-start=\"1814\" data-end=\"1841\"\u003e\n\u003cth data-start=\"1814\" data-end=\"1830\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1830\" data-end=\"1841\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1919\" data-end=\"2742\"\u003e\n\u003ctr data-start=\"1919\" data-end=\"1947\"\u003e\n\u003ctd data-start=\"1919\" data-end=\"1927\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"1927\" data-end=\"1947\" data-col-size=\"md\"\u003eSellstrom Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1948\" data-end=\"1984\"\u003e\n\u003ctd data-start=\"1948\" data-end=\"1963\" data-col-size=\"sm\"\u003eModel Series\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1963\" data-end=\"1984\"\u003eSentryWash® 90455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1985\" data-end=\"2047\"\u003e\n\u003ctd data-start=\"1985\" data-end=\"2000\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2000\" data-end=\"2047\"\u003ePedestal Mounted Emergency Eye Wash Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2048\" data-end=\"2095\"\u003e\n\u003ctd data-start=\"2048\" data-end=\"2068\" data-col-size=\"sm\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2068\" data-end=\"2095\"\u003eFloor Mounted (Plumbed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2096\" data-end=\"2148\"\u003e\n\u003ctd data-start=\"2096\" data-end=\"2109\" data-col-size=\"sm\"\u003eActivation\u003c\/td\u003e\n\u003ctd data-start=\"2109\" data-end=\"2148\" data-col-size=\"md\"\u003eFlag Handle (Optional Foot Treadle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2149\" data-end=\"2217\"\u003e\n\u003ctd data-start=\"2149\" data-end=\"2162\" data-col-size=\"sm\"\u003eValve Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2162\" data-end=\"2217\"\u003e1\/2 in IPS Chrome-Plated Brass Stay-Open Ball Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2218\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2218\" data-end=\"2245\" data-col-size=\"sm\"\u003eSpray Head Configuration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2245\" data-end=\"2271\"\u003eDual Flood Spray Heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2272\" data-end=\"2314\"\u003e\n\u003ctd data-start=\"2272\" data-end=\"2286\" data-col-size=\"sm\"\u003eDust Covers\u003c\/td\u003e\n\u003ctd data-start=\"2286\" data-end=\"2314\" data-col-size=\"md\"\u003eAutomatic Float-Off Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2315\" data-end=\"2362\"\u003e\n\u003ctd data-start=\"2315\" data-end=\"2331\" data-col-size=\"sm\"\u003eWater Filters\u003c\/td\u003e\n\u003ctd data-start=\"2331\" data-end=\"2362\" data-col-size=\"md\"\u003eIntegrated Internal Filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2363\" data-end=\"2409\"\u003e\n\u003ctd data-start=\"2363\" data-end=\"2384\" data-col-size=\"sm\"\u003eWater Supply Inlet\u003c\/td\u003e\n\u003ctd data-start=\"2384\" data-end=\"2409\" data-col-size=\"md\"\u003e1\/2 in IPS Male \/ NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2410\" data-end=\"2454\"\u003e\n\u003ctd data-start=\"2410\" data-end=\"2425\" data-col-size=\"sm\"\u003eDrain Outlet\u003c\/td\u003e\n\u003ctd data-start=\"2425\" data-end=\"2454\" data-col-size=\"md\"\u003e1-1\/4 in IPS Female \/ NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2455\" data-end=\"2491\"\u003e\n\u003ctd data-start=\"2455\" data-end=\"2476\" data-col-size=\"sm\"\u003eOperating Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2476\" data-end=\"2491\" data-col-size=\"md\"\u003e0.2–0.8 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2492\" data-end=\"2529\"\u003e\n\u003ctd data-start=\"2492\" data-end=\"2518\" data-col-size=\"sm\"\u003eMaximum Static Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2518\" data-end=\"2529\" data-col-size=\"md\"\u003e0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2530\" data-end=\"2593\"\u003e\n\u003ctd data-start=\"2530\" data-end=\"2545\" data-col-size=\"sm\"\u003eBowl Options\u003c\/td\u003e\n\u003ctd data-start=\"2545\" data-end=\"2593\" data-col-size=\"md\"\u003eImpact-Resistant Blue ABS or Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2594\" data-end=\"2650\"\u003e\n\u003ctd data-start=\"2594\" data-end=\"2614\" data-col-size=\"sm\"\u003ePedestal Material\u003c\/td\u003e\n\u003ctd data-start=\"2614\" data-end=\"2650\" data-col-size=\"md\"\u003eHot-Dipped Galvanized Steel Pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2651\" data-end=\"2688\"\u003e\n\u003ctd data-start=\"2651\" data-end=\"2666\" data-col-size=\"sm\"\u003eFloor Flange\u003c\/td\u003e\n\u003ctd data-start=\"2666\" data-end=\"2688\" data-col-size=\"md\"\u003e9 in Cast Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2689\" data-end=\"2742\"\u003e\n\u003ctd data-start=\"2689\" data-end=\"2707\" data-col-size=\"sm\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-start=\"2707\" data-end=\"2742\" data-col-size=\"md\"\u003eApprox. 15–16.5 lb (6.8–7.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Uruguay Oil Field \u0026 Safety","offers":[{"title":"Default Title","offer_id":48884167606489,"sku":"5SRA-90455","price":2247.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/9791\/2793\/files\/SellstromSentryWash_90455SeriesPedestalMountedEyeWashStation.png?v=1783066789","url":"https:\/\/pmrsafety.com\/products\/sellstrom-sentrywash%c2%ae-90455-series-pedestal-mounted-eye-wash-station","provider":"PMR Safety","version":"1.0","type":"link"}